{"id":18156,"date":"2016-04-26T10:03:57","date_gmt":"2016-04-26T01:03:57","guid":{"rendered":"http:\/\/www.webtech.co.jp\/help\/?page_id=18156"},"modified":"2021-11-05T08:49:41","modified_gmt":"2021-11-04T23:49:41","slug":"startup_dialog","status":"publish","type":"page","link":"https:\/\/www.webtech.co.jp\/help\/en\/exepress6\/startup_dialog\/","title":{"rendered":"Startup dialog"},"content":{"rendered":"<ul class=\"topicmenu clearfix\">\n<li><a href=\"#cabdrop\">Start by dropping an archive file<\/a><\/li>\n<li><a href=\"#inidrop\">Start by dropping the configuration file<\/a><\/li>\n<li><a href=\"#cmpine\">Start by specifying command line arguments<\/a><\/li>\n<li><a href=\"#senpo\">Start by using [Send to] in Explorer.<\/a><\/li>\n<li><a href=\"#compress\">Command line specified operation for EXEpress Compressor<\/a><\/li>\n<\/ul>\n<p>EXEpress 6 can be started in a variety of ways.<\/p>\n<h2 id=\"cabdrop\">Start by dropping an archive file<\/h2>\n<p class=\"clearfix\"><a href=\"https:\/\/www.webtech.co.jp\/help\/wp-content\/uploads\/2016\/04\/selecting_startup_method.png\"><img loading=\"lazy\" decoding=\"async\" class=\"alignright wp-image-18205 size-medium\" src=\"https:\/\/www.webtech.co.jp\/help\/wp-content\/uploads\/2016\/04\/selecting_startup_method-300x164.png\" alt=\"selecting_startup_method\" width=\"300\" height=\"164\" srcset=\"https:\/\/www.webtech.co.jp\/help\/wp-content\/uploads\/2016\/04\/selecting_startup_method-300x164.png 300w, https:\/\/www.webtech.co.jp\/help\/wp-content\/uploads\/2016\/04\/selecting_startup_method.png 406w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\" \/><\/a>The dialog box at right is displayed when EXEpress 6 is started by dropping an <a class=\"words\" href=\"https:\/\/www.webtech.co.jp\/help\/en\/exepress6\/words\/#archivefile\">archive file<\/a> (*.cab) on the EXEpress 6 icon.<\/p>\n<table>\n<tbody>\n<tr>\n<th>Start by initializing settings and specifying the archive file name<\/th>\n<td>\n<p>After selecting <span class=\"ctrl\">[Settings] &gt; [Initialize Settings]<\/span> on the Main Menu, the program starts in the same state as when entering the <a class=\"words\" href=\"https:\/\/www.webtech.co.jp\/help\/en\/exepress6\/words\/#archivefile\">archive file<\/a> that is dropped.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<th>Start by loading the configuration file (*.ini) with the same name and in the same location as the archive file<\/th>\n<td>\n<p>Starts in the same state as when the <a class=\"words\" href=\"https:\/\/www.webtech.co.jp\/help\/en\/exepress6\/words\/#inifile\">configuration file<\/a> (*.ini) with the same name as the <a class=\"words\" href=\"https:\/\/www.webtech.co.jp\/help\/en\/exepress6\/words\/#archivefile\">archive file<\/a> is loaded in the main dialog box.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<th>Start in a state of changing the archive filename and using the previous settings<\/th>\n<td>\n<p>Start in the same state as when entering the name of the <a class=\"words\" href=\"https:\/\/www.webtech.co.jp\/help\/en\/exepress6\/words\/#archivefile\">archive file<\/a> that is dropped while keeping the settings when the previous run completes.<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>Select one and click on the <span class=\"ctrl\">[OK] button<\/span> to open the EXEpress 6 main window.<\/p>\n<p class=\"link\"><a href=\"https:\/\/www.webtech.co.jp\/help\/en\/exepress6\/windows_exepress\/\">EXEpress 6 Main Window<\/a><\/p>\n<h2 id=\"inidrop\">Start by dropping the configuration file<\/h2>\n<p>When EXEpress 6 is started by dropping the <a class=\"words\" href=\"https:\/\/www.webtech.co.jp\/help\/en\/exepress6\/words\/#inifile\">configuration file<\/a> (*.ini) on the EXEpress 6 icon, the <a class=\"words\" href=\"https:\/\/www.webtech.co.jp\/help\/en\/exepress6\/words\/#selfextractexefile\">self-extracting executable file<\/a> is created according to the content of the configuration file and exits without displaying the EXEpress 6 main window.<\/p>\n<h2 id=\"cmpine\">Start by specifying command line arguments<\/h2>\n<p>The program can be started by passing the EXEpress 6 execution file \u201cexepress.exe\u201d to an argument.<\/p>\n<ul>\n<li>Passing the <a class=\"words\" href=\"https:\/\/www.webtech.co.jp\/help\/en\/exepress6\/words\/#archivefile\">archive file<\/a> to an argument is the same as starting by dropping the archive file.<\/li>\n<li>Passing the <a class=\"words\" href=\"https:\/\/www.webtech.co.jp\/help\/en\/exepress6\/words\/#inifile\">configuration file<\/a> to an argument is the same as starting by dropping the configuration file.<\/li>\n<\/ul>\n<p>This is convenient for creating short cuts or batch files to \u201cautomatically create a <a class=\"words\" href=\"https:\/\/www.webtech.co.jp\/help\/en\/exepress6\/words\/#selfextractexefile\">self-extracting executable file<\/a>.\u201d<\/p>\n<h2 id=\"senpo\">Start by using [Send to] in Explorer.<\/h2>\n<p>If EXEpress 6 is saved in <span class=\"ctrl\">[Send to]<\/span> in Explorer, EXEpress 6 can be started immediately by selecting an <a class=\"words\" href=\"https:\/\/www.webtech.co.jp\/help\/en\/exepress6\/words\/#archivefile\">archive file<\/a> or <a class=\"words\" href=\"https:\/\/www.webtech.co.jp\/help\/en\/exepress6\/words\/#inifile\">configuration file<\/a> in Explorer.<\/p>\n<p>EXEpress 6 can be saved in <span class=\"ctrl\">[Send to]<\/span> by saving an EXEpress 6 shortcut in the following folder.<\/p>\n<blockquote>\n<p>\\Users\\UserName\\AppData\\Roaming\\Microsoft\\Windows\\SendTo<\/p>\n<\/blockquote>\n<h2 id=\"compress\">Command line specified operation for EXEpress Compressor<\/h2>\n<p>By specifying a command line in EXEpress 6 Compressor (epcomp.exe) and starting, the <a class=\"words\" href=\"https:\/\/www.webtech.co.jp\/help\/en\/exepress6\/words\/#archivefile\">archive file<\/a> can be automatically generated.<\/p>\n<p>By specifying the following as an option when executing from the command line specifying an ini file,<\/p>\n<pre>\/ArchiveFile:[Filename]<\/pre>\n<p>the source CAB file used for processing can be switched from the one specified in the ini file.<\/p>\n<p>Also, when specifying<\/p>\n<pre>\/OutputFile:[Filename]<\/pre>\n<p>the filename of the output self-extracting EXE file can be switched from the one specified in the ini file.<\/p>\n<p>Note that command parameters can be specified in any order.<\/p>\n<h2>Specifying configuration file(epc file)<\/h2>\n<p>When the EXEpress Compressor <a class=\"words\" href=\"https:\/\/www.webtech.co.jp\/help\/en\/exepress6\/words\/#inifile\">configuration file<\/a> (epc file) name is passed to the command line, EXEpress Compressor starts by loading the specified epc file.<\/p>\n<h2>Compression by directly specifying folder name<\/h2>\n<p>When the folder name and output <a class=\"words\" href=\"https:\/\/www.webtech.co.jp\/help\/en\/exepress6\/words\/#archivefile\">archive file<\/a>name are passed to the command line, the files in the specified folder are compressed and output with the specified archive filename.<\/p>\n<p>The output <a class=\"words\" href=\"https:\/\/www.webtech.co.jp\/help\/en\/exepress6\/words\/#archivefile\">archive file<\/a>name can be omitted, and in this case a file named \u201c(source folder name).cab\u201d is output in the source folder.<\/p>\n<p>The output results are determined by the error code.<\/p>\n<pre>example:\r\n  epcomp c:\\folder d:\\out.cab\r\n  \u2192 Compress c:\\folder then output d:\\out.cab \r\n\r\n  epcomp c:\\folder\r\n  \u2192 Compress c:\\folder then output c:\\folder.cab<\/pre>\n<h2>Auto Compression by specifying epc file<\/h2>\n<p>All compression processes are performed automatically when the \/compress switch, epc filename, and output archive filename are all three specified.<\/p>\n<p> The output archive filename can be omitted. When it is omitted, a file with the name of epc file with cab as the extension is used as the <a class=\"words\" href=\"https:\/\/www.webtech.co.jp\/help\/en\/exepress6\/words\/#archivefile\">archive file<\/a>.<\/p>\n<pre>example:\r\n  epcomp \/compress c:\\sample.epc d:\\out.cab\r\n  \u2192 Output d:\\out.cab\r\n\r\n  epcomp \/compress c:\\sample.epc\r\n  \u2192 Output c:\\sample.cab<\/pre>\n<h2>Other Command<\/h2>\n<p><b>\/silent<\/b><\/p>\n<p>Specify this switch so that status display dialogs and error messages are not displayed during processing. <br \/> For example, this can be used so that extraneous error message types are not displayed during batch processing.<\/p>\n<h2>Error codes (Return value)<\/h2>\n<p>The error codes can be obtained with the ERRORLEVEL variable for Windows batch files.<\/p>\n<table border=\"0\">\n<tbody>\n<tr>\n<th style=\"text-align: center;\">Error codes<\/th>\n<td>\n<p style=\"text-align: center;\">Return value<\/p>\n<\/td>\n<\/tr>\n<tr>\n<th>0<\/th>\n<td>\n<p>Successful completion<\/p>\n<\/td>\n<\/tr>\n<tr>\n<th>101<\/th>\n<td>\n<p>The epc filename was not specified during automatic compression<\/p>\n<\/td>\n<\/tr>\n<tr>\n<th>102<\/th>\n<td>\n<p>The XML load engine failed to initialize during automatic compression<\/p>\n<\/td>\n<\/tr>\n<tr>\n<th>103<\/th>\n<td>\n<p>The epc file failed to load during automatic compression<\/p>\n<\/td>\n<\/tr>\n<tr>\n<th>104<\/th>\n<td>\n<p>No compression source file exists during automatic compression<\/p>\n<\/td>\n<\/tr>\n<tr>\n<th>105<\/th>\n<td>\n<p>The source data was defective (the tree structure was not followed) during automatic compression<\/p>\n<\/td>\n<\/tr>\n<tr>\n<th>301<\/th>\n<td>\n<p>The specified folder information was corrupted during folder specified automatic compression<\/p>\n<\/td>\n<\/tr>\n<tr>\n<th>302<\/th>\n<td>\n<p>The <a href=\"https:\/\/www.webtech.co.jp\/help\/en\/exepress6\/words\/#archivefile\">archive file<\/a> failed to output during folder specified automatic compression<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>&nbsp;<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Start by dropping an archive file Start by dropping the configuration file Start by specifying command line ar..<\/p>\n","protected":false},"author":33,"featured_media":0,"parent":18134,"menu_order":68,"comment_status":"closed","ping_status":"closed","template":"page_eng.php","meta":{"_acf_changed":false,"footnotes":""},"tags":[],"class_list":["post-18156","page","type-page","status-publish","hentry"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.webtech.co.jp\/help\/wp-json\/wp\/v2\/pages\/18156","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.webtech.co.jp\/help\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.webtech.co.jp\/help\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.webtech.co.jp\/help\/wp-json\/wp\/v2\/users\/33"}],"replies":[{"embeddable":true,"href":"https:\/\/www.webtech.co.jp\/help\/wp-json\/wp\/v2\/comments?post=18156"}],"version-history":[{"count":0,"href":"https:\/\/www.webtech.co.jp\/help\/wp-json\/wp\/v2\/pages\/18156\/revisions"}],"up":[{"embeddable":true,"href":"https:\/\/www.webtech.co.jp\/help\/wp-json\/wp\/v2\/pages\/18134"}],"wp:attachment":[{"href":"https:\/\/www.webtech.co.jp\/help\/wp-json\/wp\/v2\/media?parent=18156"}],"wp:term":[{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.webtech.co.jp\/help\/wp-json\/wp\/v2\/tags?post=18156"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}